CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE
b. Check Expiry
‘ON’ / ‘OFF’ value. When this option is set, the system will check the Expiry Date
Setting of the card that set at the Access Level. The system will not allow the card
user to access the door when the card is EXPIRED.
c. Anti-Passback
‘ON’ / ‘OFF’ value. Anti-Passback is to ensure that if the person swipes at the IN-
Reader of the door to go into the protected area, he/she must swipes at the OUT-
Reader of the door to go out from the protected area. After he/she has swiped out of
the protected are, the next valid swipe is only at the In-Reader of the door.
d. Advance Comm.
‘ON’ / ‘OFF’ value. To enable the extra communication port. (RS-232 Signal)
e. Auto-PIN1 to Auto-PIN10 (Common PIN Setting)
4 digits of number are required to set the Auto-PIN numbers. There is 10 PIN
numbers to be set. All the readers can share these PIN numbers. But the door must
set the ‘Use Common PIN Mode’ to ‘ON’ position.
To disable the PIN number, user can set the PIN number to ‘0000’ or set the PIN
TimeZone to ‘000’ (this is describe as below).
f. Auto-PIN1 TimeZone to Auto-PIN10 TimeZone
Set the TimeZone for each Auto-PIN, so that each Auto-PIN can be used within the
TimeZone setting.
To disable the PIN number, user can set the PIN TimeZone to ‘000’.
g. Facility Code
A value of 0000-9999 is allowed. If ‘0000’ is entered, the controller will ignore the
facility code encoded in the user cards. Otherwise, only user cards with the set
facility code will be accepted. The default value is ‘0000’.
CASS TECHNOLOGY SDN BHD(338857-X) 25