CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE
Special Purpose Time Zone
CASTLE-Commando has special TimeZone, namely:
a. Door #1 to Door #16 Auto Lock Release TimeZone
b. Door #1 to Door #16 Local PIN Mode TimeZone
c. Door #1 to Door #16 Card + PIN Mode TimeZone
d. Pin Mode TimeZone
e. General Purpose Output TimeZone
f. Sensor / Alarm Arm TimeZone
a. Door #1 to Door #16 Auto Lock Release TimeZone
The Automatic Lock Release Time Zone can be programmed to lock or unlock the
electric door for certain time periods. One of these features is to unlock the office
main door during office hours. After office hours, the door will be locked and users
will need to swipe their cards to enter the office.
b. Door #1 to Door #16 Local PIN Mode Time Zone
Each door (Door #1 to Door #16) can be set to its own PIN number separately.
There are two sets of PIN number to be set into each reader. The Local PIN Mode
Time Zone is used to specify the time periods when the user will need to enter the
PIN number for the specify door to access the door. Outside the PIN Mode
TimeZone, the user will not allowed to use the PIN to enter the premises.
c. Door #1 to Door #16 Card + PIN Mode TimeZone
The Card + PIN Mode TimeZone is used to specify the time periods when the users
will need to swipe their cards AND enter the PIN numbers. Outside the CARD + PIN
Mode TimeZone, the user will only need to swipe their card to gain entry. PIN entry
is not required.
d. PIN Mode TimeZone
This is a Common PIN number set in the controller. All the readers are sharing this
PIN number. The PIN Mode TimeZone is used to specify the time periods when the
user can enter the secure area by entering a PIN number. Outside the PIN Mode
TimeZone, the user will not allowed to use the PIN to enter the premises.
e. General Purpose Output TimeZone
This is a relay output that can be used for general purposes. It can be used for
controlling the lighting or ventilation systems. It can be turned ON/OFF manually or
by TimeZone controlled (Use an external relay with higher ampere).
f. Sensor / Alarm Arm TimeZone
Sensor / Alarm Arm TimeZone is used to automatically arm and disarm the alarm
system. This feature is useful for automatically arming the alarm system after office
hours and disarming during office hours. Manual arming and disarming is also
possible by entering a 6-digit arming/disarming password at the readers.