CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE
Change Card PIN Number
Using the Reader, user can change his/her Access Card PIN number. Can
change it anytime.
For example: -
First press the ‘*’ three times, you can see the indicator Green LED and Yellow
LEDs Flashing, Red LED OFF. Then swipe in the Access Card, then swipe the
access card at the reader. Finally, key in the old PIN number, follow by new PIN
number for two times to verification.
If the user forgot or lost his/her changed Card PIN number, the user can go to the
Controller to reinstall the Card again. The new Card PIN number will be the
default PIN number as given by the supplier.
Duress Alarm
Press '##' follow by normal operation to generate Duress Alarm.
For example: -
First press the ‘#’ twice at a time, then key in the valid Auto-PIN or swipe the
access card at the reader.
After key in the valid Auto-PIN or swipe the access card. The user can still open
the door like normal. But the transaction on the controller will display “Duress
Alarm” message as shown below: -
Card Reader LED Indicators
For the CASTLE-S Card Reader, there are 3 LEDs to indicate the status of the
card reader. The following table describes the status of the card reader and the
corresponding LED indications.
Card Reader Status LED Indications Door Lock Status
Normal, waiting to
read card
Yellow LED Flashing, others
OFF
Locked (If Auto Lock
Release not enable)
Valid Card Swipe
(without PIN)
Green LED ON, Yellow LED
Flashing, Red LED OFF
Unlocked
Invalid Card Swipe Green LED OFF, Yellow LED
Flashing, Red LED ON
Locked
Valid Card Swipe,
waiting for PIN
Green and Yellow LEDs
Flashing, Red LED OFF
Locked
Correct PIN entered Green LED ON, Yellow LED
Flashing, Red LED OFF
Unlocked
Wrong PIN entered Green LED OFF, Yellow LED
Flashing, Red LED ON
Locked
Duress Alarm (waiting
PIN or Access Card)
Green and Yellow LEDs
Flashing, Red LED OFF
Locked (Unlocked when
valid PIN or Access Card)
Controller Down Yellow LED ON in long time,
OFF in short time, others
OFF
Depend on the Emergency
Mode setting at the
Controller
CASS TECHNOLOGY SDN BHD(338857-X) 42